NSF, from what I have heard uses municipal wastewater that has been through a primary sedimentation process. This sounds like "normal' residential wastewater, don't you think?
The lowest flow certification is for 500 gal/day. Any person that knows anything about this field knows that homes NEVER produce this much wastewater unless something in the home is broken. If your state standards say they do, your standards are wrong. Seriously, we are talking about potty breaks, showers and laundry not Blue Fin Tuna farming. Oh....Do Americans really still have "laundry day"? I suppose so but only if the laundry is done at the local laundromat. Right? Think about it.
Why would "laundry day" matter? I suppose if the system happens to be a Failure -prone Aerated Septic Tank, the worry would be washout. (although, since those things don't work anyway they might as well be clean and meadow fresh) If we are talking about the systems using filter fabric the concern is hydraulic overload and biological clogging of the fabric.
So I take a look at this system, call it brand x, and review its sample data from a single family home producing around 150-200 gal/day and can see that it doesn't have a prayer of meeting the 245 standard of 50% removal it reportedly received while treating 500 gal/day in the NSF program. What is the real story here?
Just for fun I have pasted sample data from an NSF certified system (in red below) and sample data from a non-NSF certified Eliminite 120C (in green) collected during the same third party test. Remember this is ACTUAL data collected by a state funded third party. The NSF system is listed, for instance, as Best Available Technology (BAT) In Maryland. Really, Best??
Eliminite 120 C Standard Model
Date TN
7/10/2009 11.9287/17/2009 6.475
7/24/2009 5.171
7/31/2009 4.740
8/7/2009 4.677
8/14/2009 5.084
8/21/2009 8.685
8/31/2009 3.639
9/4/2009 10.224
9/11/2009 8.345
9/18/2009 9.213
9/30/2009 4.568
10/9/2009 6.580
10/16/2009 7.120
10/23/2009 3.520
10/30/2009 11.345
3/25/2010 11.475
4/16/2010 13.460
4/29/2010 6.370
4/30/2010 11.280
5/4/2010 9.680
5/11/2010 10.111
5/18/2010 7.870
5/25/2010 3.430
6/1/2001 4.560
6/8/2010 4.670
6/15/2010 5.375
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
NSF 245 Certified System
Date TN
7/10/2009 33.541
7/17/2009 60.700
7/24/2009 85.064
7/31/2009 69.130
8/7/2009 46.800
8/14/2009 34.991
8/21/2009 40.183
8/31/2009 56.636
9/4/2009 51.200
9/11/2009 66.248
9/18/2009 56.500
9/30/2009 67.000
10/9/2009 40.100
10/16/2009 34.700
10/23/2009 33.270
10/30/2009 21.338
3/25/2010 35.100
4/16/2010 69.200
4/29/2010 78.200
4/30/2010 84.800
5/4/2010 67.230
5/11/2010 35.700
5/18/2010 34.900
5/25/2010 66.783
6/1/2001 54.321
6/8/2010 33.760
6/15/2010 67.000